
LoadConnectorAPImodule:EnablesordisablesloadingtheAPImodulewiththefaxserver.
Order Packet Folder: This directory will be scanned for new “T” order packets. This can either be
a local directory or a UNC path to a remote directory. Mapped network drives are not supported
(except when the server is running as an application). Ensure that the service account has full
controlof)thetargetdirectory(see2.3.1ServiceAccountPermissions).
Completion Packet Folder: Completed order packets (“P” packets) will be written to this
directory. They should have their completion status checked and then deleted by the API client
application. This field can be left blank and the server will discard the completed order packet. The
only way to check if the fax was sent successfully in this case is using a report (see 2.7 Reporting
).
Scan Rate: Normally the API module will poll the order packet folder every 5 seconds. This is
normallysufficient,butifneededthepollratecanbechanged.
Suppress Page Header: Disables the identification line normally created by the fax server at the
topofthepage.
2.10.2ControllingtheNumberofPacketsReadBytheServer
Normally, the Connector API module will only read and process new packets when the Scheduled
plus Active queues have fewer than three times the faxserver’s port count. This provides good
throughput while not excessively delaying other faxes being sent by the fax server from other
sources.
Numberofpacketstoprocessattheserveriscontrolledby:
[HKLM\Software\FaxBack\AsciiPacketServer]
"PortThresholdMultiplier"(dword)multipliedbythenumberofports.
2.10.3MultipleOrderPacketFolders
The Connector API module can only read from a single order directory. In order to read packets
from multiple directories it is necessary to load multiple Connector API modules. Each instance of
the module requires its own registry key and settings, its own unique copy of the asc2cas.dll, and
itsownusertologintothefaxserverwith.
2.10.3.1CopyConnectorAPIDLL
Firstmakeauniquecopyoftheasc2cas.dllbycopyingthefileintheNETSatisFAXtion
serverinstallationdirectory.Forexample,copyittoasc2cas_2.dll.
CreateNETSatisFAXtionAccount
CreateanewaccountintheAdministrationprogramforthenewConnectorAPI
moduletologinwith.ForexampleClarityNS2.Theaccountonlyneedsuser
levelpermissions.
2.10.3.3CreateRegistryKey
Create a new uniquely named ASCIIPacketServer registry key under HKLM\Software\FaxBack to go with
the copied DLL. For example ASCIIPacketServer_2. The new registry key must at least have the
followingvalues:
CompletionDir[string]:
Set to the Completion Packet Folder to use with this instance of
theConnectorAPImodule.
SameasinASCIIPacketServer.
ProprietaryFaxBack,Inc.2014 109
Comentarios a estos manuales